site stats

Jendl 3

Web31 dic 1994 · Although JENDL-3.1 predicts various reactor characteristics much better than JENDL-2, particularly in space-dependent problems such as sodium void coefficients and C/R worths, some problems have been pointed out: The key values of uranium cores are systematically different from those of plutonium cores, the spectra in the shielding … Webused, and the compilation of JENDL-3 is in the final stage. In this review paper, brief introduction for these three libraries is given. In the next chapter, nuclear data evaluation for JENDL-1 and its benchmark tests are presented confin ing description to typical strength and weak ness. In Chap. ill, characteristics of JENDL-2

Index to BROND-2, CENDL-2, ENDF/B-6, JEF-2, JENDL-3

Web摘要: 中子学积分实验是检验评价中子核数据库质量的一种重要手段,是核数据库建设工作的一项重要内容.国际上已开展了大量的积分实验,对数据库更新起到了重要作用,国内此方面的工作开展较少.铁是核装置的重要结构材料,其快中子截面数据的精确度对新型核装置设计具有重要意义.本论文采用板 ... Web30 apr 2013 · JENDL-3.3 is the final revision of the JENDL-3 series. The problems in JENDL-3.2 were resolved by considering the results of the benchmark analyses and new measurements. Covariances were estimated for important nuclides. After JENDL-3.3, in principle, we evaluate isotopic data without producing elemental data files. ericsson rewards gateway https://jdmichaelsrecruiting.com

2. 2 Integral Testing of JENDL-3. 2 - inis.iaea.org

Web27 ago 2014 · Calculations were made based on a continuous-energy Monte Carlo code MCNP4B/4C and multi-group discrete ordinates codes ANISN and DORT. The latest version of NJOY99 was employed to generate cross-section libraries for these transport codes. Calculations with JENDL-3.2, ENDF/B-VI, FENDL-1 and FENDL-2 were also made for … WebEvaluation for JENDL-3.3 has been performed by considering the accumulated feedback information and various benchmark tests of the previous library JENDL-3.2. The major … Web5 apr 2014 · 宏观方法存由于传输速度被本底淹没曲线,根据该曲线得到缓种方法以当前人们,需持续改进中子发射曲线作者自身,早期曾用中子发射曲线,JoannM.Campbell中子先驱占优裂变产物JEFF3.1采用中子群参数Keepin制作,ENDF/B6、ENDF/B7裂变参数,JEFF3.1,选择JEFF3.114.7MeV数据的相对份额ix ... ericsson remote jobs

Integral Test of JENDL-3.3 with Shielding Benchmarks

Category:Japanese Evaluated Nuclear Data Library Version 3 Revision-2: …

Tags:Jendl 3

Jendl 3

Testing of BROND-2, JENDL-3, and ENDF/B-VI neutron data …

Web• 2002, JENDL-3.3 (337) with 209 PT’s in the URR (+ JEFF-3.1/Th) • International Handbook of Evaluated Criticality Benchmarks Experiment, ICSBEP September 2006 edition • Run … WebMaxwellian averaged cross sections, MACS, Astrophysical reaction rates, ENDF/B-VII.0, JEFF-3.1, JENDL-3.3, ENDF/B-VI.8,ROSFOND,CENDL-3.1. Results. Reference Paper. NDS 113, 3120 (2012) Calculations of Maxwellian-averaged cross sections and astrophysical reaction rates 2010 Downloads: 2012 Downloads:

Jendl 3

Did you know?

Web29 mar 2024 · Dear Norbert, you could try the JENDL HE library and see if that changes something. However, looking at your output file I’ve noticed that you used 181Ta.80c in the [Material] section. Typically nuclear data library extensions ending in .XXc designate libraries for neutron transport, not for proton reactions. But since you are interested in (p,n) … Web1 nov 2002 · @misc{etde_20350652, title = {Curves and tables of neutron cross sections in JENDL-3.3} author = {Nakagawa, Tsuneo, Shibata, Keiichi, and Kawasaki, Hiromitsu} abstractNote = {Neutron cross sections of 337 nuclides in JENDL-3.3 are presented in figures and tables. In the tables, shown are cross sections at 0.0253 eV and 14 MeV, …

Web16 dic 2024 · This study evaluated the nuclear data libraries for a small 100 Mega Watt electric (MWe) Molten Salt Reactor with plutonium fuel. The reactor has a power output of 100 MWe, which meets the demand for electricity generation in several regions or provinces outside Java Island. Several nuclear data libraries, such as JEFF 3.1, ENDF/B-VII.0, … WebNeutron cross sections of 337 nuclides in JENDL-3.3 are presented in figures and tables. In the tables, shown are cross sections at 0.0253 eV and 14 MeV, Maxwellian average cross sections (kT = 0.0253 eV), resonance integrals and fission spectrum average cross sections. The average cross sections calculated with typical reactor spectra are also tabulated.

Webcal Facility') (TRACY) in the Japan Atomic Energy JENDL-3.3 library and two former-used libraries, Research Institute. In the studies te accurate predic- JENDL-3.2') and ENDF/B_VI,6) are also discussed. tion of neutronic characteristics during power bursts is required because these characteristics control all tran- 2. Experiments WebJENDL-3.1 Iron Validation on the PCA-Replica (H2O/FE), Shielding Benchmark Experiment - JEFF/DOC-703 Pescarini, M. 1997-12-15. Scheda breve; Scheda completa; Scheda …

Web10 apr 2024 · Summary of JENDL-3.2. Purpose. To provide a Japanese standard library for fast breeder reactors, thermal reactors, fusion neutronics and shielding calculations. Number of nuclides. 340. Incident neutron energy range. 10 …

Web1 gen 2011 · At around 510 keV, the values in JENDL-3.3 and ENDF/B-VII.0 were smaller than the present result by about 20%, but those in ENDF-VI.8 were larger than the present result by about 20%. ericsson rectifierWebJENDL-3 data for 23Na. The ENDF evaluation is mainly based on the experimental data which were available then, whereas the JENDL evaluation is a mixture of measurements and theoretical predictions. It was pointed out that there ex-isted large differences in the elastic and inelastic scattering cross sections between JENDL-3.2 and ENDF/B-VI in the ericsson restructuringWeb陈国长,曹文田,王记民,于保生,唐国有 (1.中国原子能科学研究院核数据重点实验室,北京 102413; 2.北京大学物理学院核物理与核技术国家重点实验室,北京 100871) ericsson rnt44737/01WebJENDL-3.3. NOTICE: The users are requested to cite the No.1 of the papers given below for referencing JENDL-3.3. Summary of JENDL-3.3. Purpose. To provide a Japanese standard library for fast breeder reactors, thermal reactors, fusion neutronics and shielding calculations, and other applications. Number of nuclides. ericsson rof157Web2. 2. 1 Benchmark Tests of JENDL-3. 2 for Thermal and Fast Reactors Hideki Takano Japan Atomic Energy Research Institute Tokai, Ibaraki, 319-11, Japan +81-292-82-6151 … ericsson reset passwordWeb1 mar 1994 · The calculations using JENDL-3 show overall agreement with the experimental data as well as those with ENDF/B-IV. Particularly, JENDL-3 gives better results than … ericsson receptionWebJENDL-3.1 and ENDF/B VI Iron Validation on the (H2O/FE) PCA-REPLICA Shielding Benchmark Pescarini, M. 1996-09-06. Scheda breve; Scheda completa; Scheda … ericsson repair